8065C belongs to the “X-Ray Luggage Scanner” product family, which are designed for the security inspection of the big baggage&parcels, luggaes etc.
It’s widely used in the shopping malls, subways, schools, factories and other infrastructures.
◆ Digital signal and processor
◆ Continous hard work for 10000 hours
◆ Energy saving design
◆ High penetration
◆ Good quality images
◆ Wire resolution38AWG
◆ Penetration resolution:32AWG
◆ Spatial resolution:Vertical: 1.6 Horizontal: 1.6mm
◆ Penetration:43mm
◆ Organic matter resolution:1-120mm
◆ Grayscale, mixture resolution:1-40mm
◆ Inorganic resolution:0.2-12mm
◆ Effective material resolution:Compliant with GB15208.1-2018 standards
◆ single dose:≤4.5uSv(uGy)
◆ leakage dose:<1uSv/h(uGy/h)
◆ noise level:No more than 60dB
◆ conveyor belt speed:Around 0.2 m/s
◆ Conveyor belt maximum load:200kg
◆ Maximum power consumption:1.0kW
◆ safety performance requirements
◆ Compliant with GB15208.1-2018 standards
◆ Electromagnetic Compatibility Requirements:Compliant with GB15208.1-2018 standards
◆ Electrical Safety:Compliant with GB15208.1-2018 standards
◆ Environmental adaptability:Compliant with GB15208.1-2018 standards
◆ leakage current:No more than 5.0mA
◆ film security:Compliant with ASA/ISO 1600 film safty standards
◆ weight:630kg
◆ Working environment temperature/relative humidity:5℃~40℃;0%~90%
◆ Storage temperature/humidity:-20℃~+60℃/10%~90%
◆ Atmospheric pressure:86kPa~106kPa
◆ Working power:AC220V+10%~-15%,50Hz±3Hz
◆ POST:With fault self-checking function, the corresponding fault information can be displayed when a fault occurs (1. Emergency stop 2. Side panel open 3. Calibration failure 4. Acquisition system failure 5. Hard disk not found)
◆ Image Processing:With color/black and white, local increase, high penetration, low penetration, super increase, organic highlighting, inorganic highlighting, inverse color, brightening, darkening, gray sweeping, zooming, organic marking, suspicious object marking, edge enhancement processing functions
◆ image pullback:30 checked images can be played back
◆ Number of image storage:Can store 10,000 checked images
◆ real-time curve:The real-time curve can be used to detect whether the acquisition system and components are working properly
◆ time setting:System time can be set
◆ Probe setting:Can realize manual deletion of high and low energy detection board dead pixels, and display the deleted dead pixels in the display area
◆ Ray source settings:There are two ray source control modes, digital source and analog source, and can control the digital source.Set the ray source parameters
◆ Alarm system:The alarm function can be turned on and off, the alarm type of the alarm frame and sound and light alarm can be selected, and the sensitivity, minimum absorption rate, maximum absorption rate, and alarm duration can be sets
◆ Troubleshooting:It can diagnose whether the import and export light barrier, side panel switch, emergency stop switch, light source and other components are normal, and display the standard value and current value of the detected voltage
◆ Image settings:You can set the control direction of the drum operation and the movement direction of the image display
◆ software registration:It can realize software registration function, and has serial number, registration code, registration status, system time information display
◆ User login:By entering different user names and passwords to log in to the menu, only login can be used for other parameter settings
◆ User Management:Can add, delete, edit operation user name and password and set user level, restore deleted historical users
◆ authority management:Different default permissions can be set according to user level
◆ language settings:System language can be set to switch between Chinese and English
◆ log management:User operations can be monitored and user operations can be queried
◆ about:Display version and device number
◆ TIP report: report can be generated for the operation of identifying TIP after the TIP insertion function is enabled. The report content: user name, number of TIP insertions, number of marks, false positive rate, detection probability, false positive probability
◆ TIP management:It can be set to enable and disable the insertion of dangerous goods, and can set the identification time, prompt time, insertion frequency, proportion of single items, add TIP files and delete files.
◆ file management:Query, open and export inspected images
◆ Function settings:You can adjust the log level of the work, save the file time, whether to open the training function, whether to turn on Smart Roller to set
◆ Statistics:Display the working time of the system, the total working time of the ray source, the total number of luggage packages in the system, the total number of luggage packages this time, and the above data can be cleared
◆ System parameter settings:Export data, pictures, backup directory can be selected, motor type,
Select and adjust the detector type, whether to open the debugging mode, model, and gain.You can enter the corresponding IP address on the network connection to achieve the sharing function, there are in the system settings。The corresponding software can realize the system upgrade